- Power Meters[6]
- Circuit Breakers[6]
- Energy Meters[6]
- Voltage Meters[6]
- Current Meters[6]
- Flow Meters[3]
- Fiber Optic Equipment[6]
- Other Electronic Measuring Instruments[1]
- Other Motor Accessories[6]
- Motor Controller[6]
- Remote Control[1]
- Solar Energy Systems[4]
- Transformers[6]
- Electronic & Instrument Enclosures[3]
- Contact Person : Mr. Zhou Jackey
- Company Name : Zhuhai Pilot Technology Co., Ltd.
- Tel : 86-756-3629673,3629699
- Fax : 86-756-3629600,3629700 Address: No.15, Keji 6 Road, Chuangxin Haian, Tangjia Hi-tech Zone, Zhuhai, Guangdong Zip: 519085 Country/Region: China (Mainland) Province/State: Guangdong
- Address : Guangdong,Zhuhai,No.15, Keji 6 Road, Chuangxin Haian, Tangjia Hi-tech Zone, Zhuhai, Guangdong
- Country/Region : China
- Zip : 519085
Related Product Searches:Modbus RTU to BACnet - Network gateway,High Quality,Modbus RTU to BACnet, modbus rtu rs485,Modbus RTU to BACnet
PILOT Point Expansion unit, type HPE - BNMOD, is for integration of Modbus RTU slave devices in to BACnet MS/TP networks. Multiple Modbus RTU devices of any mix may be connected to the HPE-BNMOD for read/write access of up to 250 data-points. All points may be individually scaled and multiple points representing Modbus registers which use multiple Words may be combined so that only one Object Instance representing the scaled multiple Word register value needs to be read up by the BMS.Application Data Primary network protocol:BACnet MS/TPSub-network protocol: Modbus RTU ----------------------------------------------------Administration points:Point 1- Diagnostic counter resetPoint 2- BACnet comms error count Point 3- Modbus comms error count Point 1000- BACnet node Point 1001- BACnet baud rate Point 1002- Modbus baud rate / config.DI- BACnet global Device Instance MM- Max MasterSV- System Vendor ID ------------------------------------------------------------------------Modbus RTU data points:250 total, point 4...253 ------------------------------------------------------------------------Supported Modbus RTU functions:01- Read (write) Coil status 02- Read Discrete Input03- Read (write) Holding Register04- Read Input Register ------------------------------------------------------------------------Comm speed selection, BACnet MS/TP:2400, 4800, 9600 (default), 19200, 38400, 76800Comm speed selection, Modbus subnet:2400, 4800, 9600 (default), 19200Modbus subnet comm configuration:7/8 data bits ¨C Odd/Even/No parity ¨C 1/2 stop bits(default ¨C 8N1)
T/T, L/C |
8 |
5 Day(s) |
YES |
Gaoxiong,Shenzhen,Zhuhai |
Africa, Eastern Europe, Hong Kong/ Macao/ Taiwan, Japan & Korea, Latin America, Mainland China, Middle East, North America, Northern Europe, Oceania, South Asia, Southeast Asia, Western Europe |
Modbus RTU to BACnet - Network gateway